Multi-Detection Microplate Readers |
FlexStation® 3 microplate reader |
| |
|
|
 |
FlexStation 3 is a dual-monochromator, multi-detection microplate reader with 6-384 microplate reading capability. Based on Molecular Devices' SpectraMax® M5 e platform, this five-mode reader addresses multiple application technologies including: absorbance(UV-Vis) (200 – 1000 nm), fluorescence intensity (250 – 850 nm), fluorescence polarization (400 – 750nm), luminescence (250 – 850 nm) and time-resolved fluorescence (250 – 850 nm). |
 |
FlexStation 3 offers automated pipetting using the 8- or 16-channel pipettor to improve assay quality and increase throughput. For fast, kinetic cell-based assays, throughput is increased when a column of wells are pipetted, read, and analyzed simultaneously rather than one well at a time. |
 |
When utilizing 8- or 16-channel pipettors, assays are expanded to include calcium mobilization assays, membrane potential assays and fast luminescence applications. |
 |
With SoftMax ® Pro software, PathCheck automatically normalizes the well absorbance to a cuvette equivalent pathlength of 1 cm —similar to using 96 or 384 cuvettes simultaneously. PathCheck allows you to eliminate standard curves and, for compounds with a known absorptivity, concentration can be calculated directly from absorbance. |
 |
The FlexStation 3 offers the additional benefit of being certified for the Cisbio HTRF assay. |
 |
Software has ability to design custom assay protocols or customize existing protocol to create meaningful reports, graphs, and multi-plate summaries, including data trend analysis. |
|
|
| |
SpectraMax® M5/M5e Microplate Reader |
| |
|
 |
SpectraMax M5/M5 e Microplate Reader is a dual-monochromator, multi-detection microplate reader with 6-384 microplate, and top- and bottom-reading capability. Detection modalities include absorbance (UV-Vis) (200 – 1000 nm), fluorescence intensity (250 – 850 nm), fluorescence polarization (400 – 750 nm), time-resolved fluorescence (250 – 850 nm) and luminescence (250 – 850 nm). |
 |
This reader also has a three-mode cuvette port that enables absorbance (UV-Vis) (200 – 1000nm), fluorescence intensity (250 – 850 nm), and luminescence (250 – 850 nm). |
 |
With SoftMax ® Pro software, PathCheck automatically normalizes the well absorbance to a cuvette equivalent pathlength of 1 cm —similar to using 96 or 384 cuvettes simultaneously. PathCheck allows you to eliminate standard curves and, for compounds with a known absorptivity, concentration can be calculated directly from absorbance. |
 |
This reader has linear plate shaking and temperature control capability. |
 |
The M5 e offers the additional benefit of being certified for the Cisbio HTRF assay. |
 |
Software has ability to design custom assay protocols or customize existing protocol to create meaningful reports, graphs, and multi-plate summaries, including data trend analysis. |
|
|
|
| |
SpectraMax® M2/M2eMicroplate Readers |
| |
|
|
|
 |
|